Search In this Thesis
   Search In this Thesis  
العنوان
Effect of Fins Material on the Performance of Stratified Chambers Gas to Gas Heat Exchanger with Porous Medium\
المؤلف
Khalil,Mohamed Medhat Hussein
هيئة الاعداد
باحث / محمد مدحت حسين خليل
مشرف / حسين زكى بركات
مشرف / حمدي أحمد حسين أبوطالب
مناقش / رمضان محمد عبدالعزيز عامر
تاريخ النشر
2020
عدد الصفحات
120p.:
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
الهندسة الميكانيكية
تاريخ الإجازة
1/1/2020
مكان الإجازة
جامعة عين شمس - كلية الهندسة - قسم هندسة القوى الميكانيكية
الفهرس
Only 14 pages are availabe for public view

from 144

from 144

Abstract

An experimental study was carried out to investigate the effect of fin material on the performance of stratified chambers gas to gas heat exchanger with and without porous media. The target of these experiments was to study the change of the rate of heat transfer under different hot and cold air stream rates, different porous material thicknesses and different hot air inlet temperatures. Using two different fin materials facilitate the investigation of the heat exchanger performance when using steel and aluminum fins. In additional to the heat exchanger performance in the absence of porous material and its presence is obtained. The determination of the optimum operating parameters to achieve maximum total heat recovery ratio is also investigated.
The test rig used in these experiments consists of the air supply system, flow and temperature measurement instruments, heating system with its control system and five heat exchanger chambers, each chamber provided with corrugated fins. The experimental study showed that using aluminum fins instead of steel fins had much improvement on the performance of the heat transfer rate. While adding the porous material to the heat exchanger chambers leads to improvement of the heat transfer rate on the expense of an increase in pressure drop.
In case of aluminum fins, the porous material thickness is 70 mm and the hot air stream inlet temperature is 400°C, the heat recovery ratio increased to 0.822, at 0.5 m3/min volume flow rate of the cold and hot air streams. While in case of steel fins with the same conditions of the hot air inlet temperature, porous material thicknesses and the volume flow rates of the cold and hot air streams, the heat recovery ratio was 0.537. It is concluded that in aluminum fins case the heat recovery ratio increases by approximately 53% of the case of the steel fins.