ENHANCEMENT OF THE CATHODIC PROTECTION SYSTEM EFFICIENCY OF BURIED METALLIC PIPES TO LIMIT ENVIRONMENTAL POLLUTION RISKS RESULTING from LEAKAGE/
الناشر
Ain Shams university.
المؤلف
Noamy, Eman Mohamed Saad Eldeen.
هيئة الاعداد
مشرف / Saad El-Deen Mohamed Desouky
مشرف / Ahmed Shawki Abdel-Ghany
مشرف / Saad El-Deen Mohamed Desouky
باحث / Eman Mohamed Saad Eldeen Noamy
الموضوع
ENHANCEMENT . CATHODIC PROTECTION SYSTEM. BURIED METALLIC PIPES.
تاريخ النشر
2011
عدد الصفحات
p.:164
اللغة
الإنجليزية
الدرجة
الدكتوراه
التخصص
السلامة ، والمخاطر ، والموثوقية والجودة
تاريخ الإجازة
1/1/2011
مكان الإجازة
جامعة عين شمس - معهد البيئة - Environmental Engineering
الفهرس
Only 14 pages are availabe for public view

from 164

from 164

Abstract

The present work investigates - on a laboratory scale - the effect of anodes position relative to cathodically protected condensed buried piping area. For this reason three identical sets of steel bars of two different lengths and three different diameters (representing pipes) were weighed and installed in three separate basins on identical racks and immersed in NaCl solution of same concentration 3.4 wt %.
Three different anode configurations were applied, one for each bar set as follows: Configuration A (distributed) small anodes suspended uniformly in between steel bars oriented parallel to the long bars and connected in parallel to the positive terminal; Configuration B (close) one main anode laid on the bottom of the basin at the centre of the bar set and oriented parallel to the long bars; and Configuration C (remote) one main anode suspended on the basin side at the middle level of bars set and oriented parallel to the short bars.
The experimental system was energized in parallel through a stabilized DC source. Prior to system energization the polarized native potential for all bars in all basins was (0.45 V) relative to zinc reference electrode.
Daily recording of system parameters for the three sets was carried out, measurements included:
(i) Potential difference between steel bars and electrolyte taken at four points for each bar for two conditions ON (protected current applied) and OFF (immediately after switching of protection current) pure zinc reference electrode was used for this purpose;
(ii) Current consumption for each basin; and
(iii) Driving voltage for each basin.
Elaboration of results was implemented in the following fashion:
a- The average potential difference of the four ON/OFF readings for each bar were calculated and plotted against time all along the test period (60 days).
b- The averages of daily readings for each bar were averaged to a gross average value over the test period.
c- The gross average ON and OFF readings were plotted on a bar diagram for each bar in each basin, in order to evaluate the degree of polarization during the test period and consequently the average potential shift.
d- Electric current for each basin was measured at the same time of potential measurement and the gross ampere-hour consumed during the test period was calculated for each basin separately.
By the end of test period the bars were cleaned in diluted HCL according to relevant standards and weighed. Reduction in weight represents corrosion loss.
Examination of obtained experimental results revealed the following features:
1- Bars in the three basins suffered from metal loss to different degrees which indicate presence of interference current of different values in all basins. Minimum loss was in basin (C) than (A) [doubled that of (C)] then (B) four times as that of (C).
2- Basin (C) showed the best performance of CP system regarding potential and stability followed by basin A and the worst was basin B.
3- Minimum current consumption was in basin (A) then (C) approximately, 1.65 that in (A) and the maximum was in basin (B) which was four times that of basin (A).
4- Best protection level was observed in basin (C) then (A) and minimum protection in basin (B).
5- Maximum protection shift was in basin (C) then Basin (A) then basin (B).
6- In general performance of basin (C) was the most favorable.
Potential variation with time shows the following:
1- The general trend of basin (C) is the increase of protection level with time along the test period which is attributed to systematic precipitation of calcium/magnesium deposits on the bars surfaces.
2- Regarding basin (A) the average protection level is almost the same along the test period which is an indication of steady state with constant amount of interference current flowing in between different bars.
3- As for basin (B) completely unsteady state was prevailing, severe interference currents flew in between different bars, most probably due to substantial proximity effects.
from above the following conclusions can be made:
• In relatively small areas crowded with pipes close single anode (as in basin B) are absolutely not recommended since it leads to unsteady protection performance due to severe interference and proximity effect.
• Remote anode position proved to be the optimum case.
• Performance of systems with distributed anodes comes in between remote and close systems.
Finally, the thesis includes intensive review of the environmental impacts and damages recorded nationally and internationally caused by corrosion leaks in piping systems. Direct and indirect effects, monitoring, treatment of oil spills are also induced with particular emphasis placed on the relevant international treaties.