Search In this Thesis
   Search In this Thesis  
العنوان
BEHAVIOR OF TWO WAY RC SLABES STRENGTHENED WITH HYBRID FRP LAMINATES
المؤلف
Awry Mahmoud Abd-Elhafez,Moataz
هيئة الاعداد
باحث / Moataz Awry Mahmoud Abd-Elhafez
مشرف / Amr Ali Abdelrahman
مشرف / Tamer Hassan Kamal Elafandy
الموضوع
FRP Types, Products, Components and Properties-
تاريخ النشر
2010.
عدد الصفحات
199.p:
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
البناء والتشييد
تاريخ الإجازة
1/1/2010
مكان الإجازة
جامعة عين شمس - كلية الهندسة - Structural Engineering Department
الفهرس
Only 14 pages are availabe for public view

from 199

from 199

Abstract

In the last two decades, the use of advanced composite materials such as
fiber reinforced polymers, (FRP), in strengthening reinforced concrete,
(RC), structural elements have been increasing. Researches, design
guidelines, and codes concluded that externally bonded FRP could
increase capacity of RC elements efficiently. However, the linear stressstrain
characteristics of FRP up to failure and lack of yield plateau have a
negative impact on the overall ductility of the strengthened RC elements.
Strengthening of two-way slabs with FRP in the two directions represents
a challenge due to the anticipated reduction in the strength and ductility
at onset of failure of FRP in one direction. Not only the linear
characteristics of FRP will reduce the slab ductility but also the released
energy caused by rupture or bond failure of FRP in one direction, which
will affect the bond between the concrete and FRP in the other direction.
Use of two types of FRP laminates, which consists of a combination of
either carbon and glass fibers or glass and aramid fibers change the
behavior of the material to a non-linear behavior (Blarabi et.al.1999) and
(Hosny et.al.2005). This thesis aims to study the performance of
reinforced concrete two-way slabs strengthened by FRP laminates in two
directions The experimental program consists of a total of eight RC two-way slabs
with overall dimensions equal to 1500 x 1500 x 70-mm with clear spans
equal to 1400 x 1400-mm. The slabs were tested under distributed
loading up to failure in order to examine its flexural behaviour. Different
fiber types, orientation and different percentages of CFRP and GFRP
were attached on the slabs to predict the best strengthening scheme. Ananalytical
model based on the stress-strain characteristics of concrete,
steel and FRP was adopted and a good agreement was obtained with
experimental results.Keywords: CFRP, Composite material, GFRP, HFRP, Hybrid,
Reinforced Concrete Strengthening and Two Way Slab.